BACKLUND     

 

Home
Up

  

 

 

 

Weiden Abwasserverdunstungsanlage ohne Ablauf

"On-Site Wastewater Treatment Research" "Assessment of disposal options for treated wastewater from single houses on low permeability subsoils".
Forschungsprojekt "Science, Technology, Research & Innovation for the Environment" (STRIVE).                              http://onsiteresearch.ie/ 

BACKLUND nimmt teil im 3-Jährige Forschungsprojekt (2011 - 2014) auf Irland für Irlands EPA (Umweltbehörde).

Arne Backlund ist als Expertteilnehmer Teil des Projektteams in Zusammenarbeit mit 3 Irische Universitäten im Bereich Weiden Abwasserverdunstungsanlagen und "Sustainable Sanitation / Ecological Sanitation".  

Anlage für Abwasserplan Nummer 2/September 2011 - für Klinteby/Karrebækstorp. Bewertung von Weidenverdunstungsanlagen über Technology und Wirtscaftlichkeit. Beratung und Projektarbeit für Niras A/S und Næstved Gemeinde. 2010 - 2011.

Weidenverdunstungsanlagen im Vergleich zu traditionellen Abwasserkanalisation im Freiland als vorgesehen in der genehnigten zur heutige Abwasserplanung in Næstved Gemeinde von 2009.

Projektarbeit für NK-Spildevand A/S in Zusammenarbeit mit Nielsen & Risager A/S in 2009 - 2010 und mit Bericht:  NK-Spildevand A/S, Nielsen & Risager A/S, Backlund ApS 2010: Erklärung - Weiden Verdunstungsanlagen als alternative zur geplanten Abwasserkanalization  " Anlage zur bestehenden Abwasserplanung" Naestved 2010 (In Dänisch).

Entwässerung von Bio-Schlamm in "GeoTubes" mit Weiden.

Arne Backlund liefert Beratung und Weiden (2010) zum Test an der Zentral Kläranlage in Næstved.

Weiden Verdunstungsanlagen und "Sustainable Sanitary Solutions".

Arne Backlund beratet (2009-2010) Gemeinde Næstved bei Alternative zur Zentrale Abwasserentsorgung.   

 

Human wastes/resources have been used on land since ancient times. A sewage irrigation system commenced at Bunslaw, Germany in 1531 and was in operation for over 300 years.

Loading wastewater to a vegetation bed without outlet is a much more recent phenomenon.

Willows are especially suited for this purpose due to a very large evapotranspiration ability, flexible root development and ability to supply the roots with air.

The oldest known Willow Evaporation System - Willow Wastewater Cleaning Facility, was established in 1991/1992 and has been running since then.

It is located in Tappernøje by "Pilehuset" a shared living complex as a part of an institution for handicapped "Marjatta" and receives wastewater from 11 persons + precipitation.

BACKLUND has monitored the system from the start and has among others in a project in a co-operation with the county ordered by the Danish Environmental Protection  documented design, construction and running. Inlet of wastewater, precipitation, willow production and evapotranspiration.

We estimate that 1.500 - 3.000 willow beds have been constructed.

With proper design, dimensions, constructions and maintenance the experiences are very good.

 

Wasserbilanze

 

Anlage

Oase Wirkung

Wäscheleine Wirkung

 

Arealbedarf nach Grid Zellen in Dänemark - m2/m3 Abwasser

Weiden Abwasserverdunstungsanlage auf Møn, Dänemark April 2004

Februar 2005

August 2005

 November 2008

.Last modified:  07.07.2016  backlund@backlund.dk   +45 60931453   Holmebjerg 21, DK-2950 Vedbæk Danmark